Customization: | Available |
---|---|
Application: | Construction, Overhead, Underground, Industrial, Power Station |
Voltage: | High Voltage Cable |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Aerial Bundled Cable
Aerial Bundled Cable Single Core is used primarily for 600V overhead secondary Power distribution lines. It is not an electrically insulated conductor and is treated as a bare conductor when installed.
Code Name |
Size AWG or MCM |
Strand |
Insulation Thickness(mls) |
Outside Diameter(inches) |
Rated Strength(lbs) |
Weight |
Ampacity(Amps) XLPE |
|
XLPE |
Poly |
|||||||
AAC |
||||||||
Apple |
6 |
Solid |
30 |
.222 |
445 |
33.0 |
32.0 |
105 |
Pear |
4 |
Solid |
30 |
.264 |
675 |
48.5 |
47.3 |
135 |
Apricot |
4 |
7/w |
30 |
.285 |
790 |
51.5 |
50.8 |
140 |
Peach |
2 |
7/w |
45 |
.373 |
1220 |
87.1 |
84.0 |
180 |
Quince |
1/0 |
7/w |
60 |
.477 |
1790 |
140.7 |
135.6 |
240 |
Code Name |
Size AWG or MCM |
Strand |
Insulation Thickness(mls) |
Outside Diameter(inches) |
Rated Strength(lbs) |
Weight |
Ampacity(Amps)
|
|
XLPE |
Poly |
|||||||
ACSR |
||||||||
Walnut |
6 |
6/1 |
30 |
.258 |
1131 |
49 |
47 |
105 |
Butternut |
4 |
6/1 |
30 |
.303 |
1170 |
71.8 |
70.0 |
135 |
Hickory |
4 |
7/1 |
30 |
.309 |
2240 |
81.6 |
79.8 |
135 |
Pignut |
2 |
6/1 |
45 |
.397 |
2710 |
118.1 |
114.8 |
180 |
Beech |
2 |
7/1 |
45 |
.405 |
3460 |
134.1 |
130.7 |
180 |
Chestnut |
1 |
6/1 |
45 |
.434 |
3370 |
145.5 |
141.8 |
210 |
Almond |
1/0 |
6/1 |
60 |
.506 |
4160 |
190.4 |
184.9 |
235 |
Pecan |
2/0 |
6/1 |
60 |
.554 |
5040 |
234.2 |
227.9 |
270 |
Filbert |
3/0 |
6/1 |
60 |
.607 |
6290 |
288.5 |
281.4 |
305 |
Buckeye |
4/0 |
6/1 |
60 |
.666 |
7930 |
356.5 |
348.5 |
345 |
Hackberry |
266.8 |
18/1 |
60 |
.711 |
6540 |
354.8 |
346.8 |
435 |
ALLOY 6201-T81 |
||||||||
Hornbeam |
4 |
7/w |
30 |
.310 |
1480 |
62.1 |
60.1 |
145 |
Linden |
2 |
7/w |
45 |
.406 |
2520 |
96.1 |
93.3 |
190 |
Oilnut |
1/0 |
7/w |
60 |
.518 |
4010 |
166.1 |
160.0 |
250 |
Waterash |
2/0 |
7/w |
60 |
.567 |
4850 |
203.3 |
196.4 |
290 |
Shellbark |
3/0 |
7/w |
60 |
.622 |
6110 |
249.4 |
241.4 |
335 |
Planetree |
4/0 |
7/w |
60 |
.683 |
7700 |
307.3 |
298.1 |
385 |
Copper Core PVC Insulation Wire BV1.5
Building wire is fit for AC rated voltage 450/750V and below of domestic electrical appliances of smaller size motorized tools of instruments of various meters and motorized lighting installations.
Model |
Name |
BV |
Copper Core PVC Insulation Wire |
BLV |
Aluminum Core PVC Insulation Wire |
BVR |
Copper Core PVC Insulation Flexible Wire |
BVV |
Copper Core PVC Insulation PVC Sheath Round Wire |
BVVB |
Copper Core PVC Insulation PVC Sheath Flat Wire |
BLVVB |
Aluminum Core PVC Insulation PVC Sheath Flat Wire |
BV-90 |
Copper Core Heat-resistance 105oC PVC Insulation |
BV BLV(BV-90)450/750V
Nominal Section (mm2) |
No/Dia.of Core (mm) |
Max, O.D (mm) |
Reference Weight (kg/km) |
Conductor Resistance at 20oC≤(Ω/km) | ||
Copper | Aluminum | Aluminum | Copper | |||
1.5(A) | 1/1.38 | 3.3 | 20.3 | 12.1 | ||
1.5(B) | 7/0.52 | 3.5 | 21.6 | 12.1 | ||
2.5(A) | 1/1.78 | 3.9 | 31.6 | 17 | 11.8 | 7.41 |
2.5(B) | 7/0.68 | 4.2 | 34.8 | 7.41 | ||
4(A) | 1/2.55 | 4.4 | 47.1 | 22 | 7.39 | 4.61 |
4(B) | 7/0.85 | 4.8 | 50.3 | |||
6(A) | 7/0.85 | 4.8 | 50.3 | 29 | 4.91 | 3.08 |
6(B) | 7/1.04 | 5.4 | 71.2 | 3.08 | ||
10 | 7/1.35 | 7.0 | 119 | 62 | 3.08 | 1.83 |
16 | 7/1.70 | 8.0 | 179 | 78 | 1.91 | 1.15 |
25 | 27/2.04 | 10.0 | 281 | 118 | 1.20 | 0.727 |
35 | 27/2.52 | 11.5 | 381 | 156 | 0.868 | 0.524 |
50 | 19/1.78 | 13.0 | 521 | 215 | 0.641 | 0.387 |
70 | 19/2.14 | 15.0 | 734 | 282 | 0.443 | 0.268 |
95 | 19/2.52 | 17.5 | 962 | 385 | 0.320 | 0.193 |
120 | 37/2.03 | 19.0 | 1180 | 431 | 0.253 | 0.153 |
150 | 37/2.25 | 21.0 | 1470 | 539 | 0.206 | 0.124 |
185 | 37/2.52 | 23.5 | 1810 | 666 | 0.164 | 0.0991 |
240 | 61/2.25 | 26.5 | 2350 | 857 | 0.125 | 0.0754 |
300 | 61/2.52 | 29.5 | 2930 | 1070 | 0.100 | 0.0601 |
400 | 61/2.85 | 33.0 | 3870 | 1390 | 0.0778 | 0.0470 |
Code Name | Size (KCM) | Strand | Approx.EC Cond with Equivalent Resistance | Stranding | Diameter(in) | Cross Sectional Area (Sq in) | Weight per 1000ft (lbs) | Rated Strength (lbs) | Resistance Ohms/1000ft (lbs) | ||
Individual Wires | Complete Cable | DC @ 20ºC | AC@ 75ºC | ||||||||
Akron | 30.58 | 7/w | 6 | 6/1 | .0661 | .198 | .0240 | 28.7 | 1,110 | .659 | .785 |
Alton | 48.69 | 7/w | 4 | 6/1 | .0834 | .250 | .0382 | 45.7 | 1,760 | .414 | .493 |
Ames | 77.47 | 7/w | 2 | 6/1 | .1052 | .316 | .0608 | 72.7 | 2,800 | .260 | .310 |
Azusa | 123.3 | 7/w | 1/0 | 6/1 | .1327 | .398 | .0968 | 115.7 | 4,460 | .163 | .195 |
Anaheim | 155.4 | 7/w | 2/0 | 6/1 | .1490 | .447 | .1221 | 145.9 | 5,390 | .130 | .154 |
Amherst | 195.7 | 7/w | 3/0 | 6/1 | .1672 | .502 | .1537 | 183.7 | 6,790 | .103 | .123 |
Alliance | 246.9 | 7/w | 4/0 | 6/1 | .1878 | .563 | .1939 | 231.8 | 8,560 | .0816 | .0973 |
Butte | 312.8 | 19/w | 266.8 | 26/7 | .1283 | .642 | .2456 | 293.6 | 11,000 | .0644 | .0769 |
Canton | 394.5 | 19/w | 336.4 | 26/7 | .1441 | .721 | .3098 | 370.3 | 13,300 | .0511 | .0610 |
Cairo | 465.4 | 19/w | 397.5 | 26/7 | .1565 | .783 | .3655 | 436.9 | 15,600 | .0433 | .0518 |
Darien | 559.5 | 19/w | 477.0 | 26/7 | .1716 | .858 | .4394 | 525.5 | 18,800 | .0360 | .0431 |
Elgin | 652.4 | 19/w | 556.5 | 26/7 | .1853 | .927 | .5124 | 612.4 | 21,900 | .0309 | .0371 |
Flint | 740.8 | 37/w | 636.0 | 26/7 | .1415 | .991 | .5818 | 695.5 | 24,400 | .0272 | .0327 |
Greely | 927.2 | 37/w | 795.0 | 26/7 | .1583 | 1.108 | .7282 | 870.4 | 30,500 | .0217 | .0263 |
Using features:
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.
2. No. of core: Single-core, Three-core.
3. The highest allowed operating temperature of conductor for long-term working is 90ºC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250ºC.
4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0ºC when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test:.
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
Control Cable
Used as power and connecting cables in mechanical engineering for tooling machinery, control unit, production lines, transportation equipment, conveyor and assembly lines as well as in plant construction under the circumstance that the rated voltage is up to 450/750V AC.
Product Type
Type | Name | Section Area (mm2) | No.of Core | Application Site |
KVV | Copper Conductor,PVC Insulated and Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors, in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP | Copper Conductor PVC Insulated and Sheathed,Braiding Shielded Control Cable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors, in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP2 | Copper Conductor PVC Insulated and Sheathed,Copper-tape Screened Control Cable | 0.75 1.0 1.5 2.5 | 4-10 | Permanent installation indoors,i n cable ditches or pipes where shielding is required |
4 6 | 7-61 | |||
10 | 4-10 | |||
KVV22 | Copper Conductor PVC Insulated and Sheathed,Steel tape Armored Control Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors, in cable ditches,Be able to withstand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-14 | |||
KVVR | Copper Conductor PVC Insulated and Sheathed,Flexible Control Cable | 0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KVVRP | Copper Conductor PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable | 0.5 0.75 1.0 | 4-61 | Installation indoors where flexibility shielding and movability are required |
1.5 2.5 | 4-48 | |||
KYJV | CopperConductor XLPE Insulated and PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors, in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJVP | Copper Conductor XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors, in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJV22 | CopperConductor,XLPE Insulated,Steel-tape Armoured,PVCSheathed Control Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors, in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVP2 | CopperConductor,XLPE Insulated,Copper tape Screened,PVCSheathed Control Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors, in cable ditches or pipes where shielding is required |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVR | CopperConductor,XLPE Insulated,PVCSheathed Flexible Control Cable | 0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KYJVRP | CopperConductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable | 0.5 0.75 1.0 | 4-61 | |
1.5 2.5 | 4-48 | Installation indoors where flexibility shielding and movability are required |
ASTM 600/1000v | |||||||||||
Core |
AWG | Structure Size (mm) | Copper cable (kg/km) | ||||||||
Conductor | Insulation | Concentric conductor | Outer sheath | ||||||||
Single wire | XLPE | Single wire | UV-PVC | ||||||||
No. | Dia. | Thick | No. | Dia. | Thick | Dia. | |||||
1 | 16 | 7 | 0.49 | 1.14 | 39 | 0.321 | 1.14 | 6.82 | 81.46 | ||
1 | 10 | 7 | 0.98 | 1.14 | 34 | 0.511 | 1.14 | 8.67 | 172.04 | ||
1 | 8 | 7 | 1.23 | 1.14 | 25 | 0.643 | 1.14 | 9.68 | 221.58 | ||
1 | 6 | 7 | 1.55 | 1.14 | 25 | 0.813 | 1.14 | 10.98 | 160.50 | ||
1 | 4 | 7 | 1.96 | 1.14 | 27 | 1.020 | 1.14 | 12.62 | 509.26 | ||
IEC 60502-1 IEC 60228 600/1000v | |||||||||||
Size (mm2) | Structure Size mm | Copper cable (kg/km) | |||||||||
Concuctor | Insulation | Concentric conductor | Outer sheath | ||||||||
Single wire | Dia. | PVC | Single wire | UV-PVC | |||||||
No. | Dia. | Thick | No. | Dia. | Thick | Dia. | (kg/km) | ||||
10 | 7 | 1.35 | 4.05 | 1.55 | 20 | 0.85 | 1.4 | 11.79 | 301.55 | ||
16 | 7 | 1.7 | 5.1 | 1.55 | 32 | 0.85 | 1.4 | 12.84 | 431.7 | ||
25 | 7 | 2.14 | 6.42 | 1.6 | 29 | 1.13 | 1.5 | 15.02 | 647.46 | ||
Aluminum Cable | |||||||||||
16 | 7 | 1.7 | 5.1 | 1.55 | 26 | 1.13 | 1.4 | 13.42 | 244.16 | ||
25 | 7 | 2.14 | 6.42 | 1.6 | 29 | 1.13 | 1.5 | 15.02 | 307.3 | ||
35 | 19 | 1.53 | 7.65 | 1.65 | 27 | 1.35 | 1.6 | 16.99 | 390.15 |
Zhengzhou Jinshui Industry & Commerce Co.,Ltd is a professional cable manufacturer and exporter with more than 20 years experience, located in Zhengzhou, China. Products mainly include bare conductor, aerial bundled cable(ABC), building wire, XLPE insulated Power Cable, coaxial cable, etc. With high-quality products and professional service, we have gained the trust from many customers and established long-term business relationship with them. Products have been exported to more than 30 countries.
1.Professional production lines, experienced worker, ensure the production of every thing is fine and accurate.
2.We choose excellent raw materials carefully to ensure the quality and meet the need of customers.
3.Mechanical testing of Cables is done to determine the quality and mechanical characteristics before delivery.
(1). Are you the factory or trading company?
We are the manufacturer and 18 years gold supplier on Made in China. We are engaged in exporting cables for nearly 20 years.
(2).When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
(3).How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
(4). What is the payment terms?
30% deposit by T/T,70% T/T after checking the copy of B/L. Or irrevocable L/C at sight .
(5).What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.
Welcome your kind enquiry!!!