1. Applications
AAC bare conductor has been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
2. Service Performance
AAC bare conductor
(1).The permissible long-time operating temperature for aerial conductors is 70oC.
(2). Under the circumstance that rare climate is occurring and ice coverage rate low in heavy ice area,the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.
(3). When connecting conductors,the conductor beside the connecting tube cant be prominent.Otherwise,the force on the operating conductors will be unbalanced. After connectors are installed,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.
(4).Under installation,the arc downing stress of all the conductors should be the same.With in the permissible distance of crossing buildings or dropping to the ground,the stress can be 10-15% higher than regular stress.
3. Product Performance
AAC bare conductor
(1).The electrical performance of AAC and ACSR is indicated in DCΩ/km(20oC).The resistivity of the hard aluminum wire for stranded wires is not greater than 28.264 nΩ. m of international standard value.
(2).The rated tensile strength of AAC is denoted with the result of total cross-section of all aluminum conductors multiplied by min.tensile of corresponding size specified in the standard for aluminum wire.
(3).The rated tensile strengh of ACSR is denoted with sum of all aluminum conductorstensile strength and steels tensile strength.
a.The tensile strength of all aluminum conductors is denoted with the result of all cross-sections of aluminum conductors multiplied by min.tensile strength of corresponding size specified in the standard for aluminum wire.
b.The tensile strength of all steel wire is denoted with the result of all cross-sections of steel wires multiplied by the stress at 1% elongation of corresponding size specified in the standard for steel wire.
4. Material Standard
AAC bare conductor
(1).The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889:1987).
(2).The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.
(3).Production can be arranged according to customers requirements for material standard,etc.
5.Product pictures
AAC bare conductor
6. Part of the specification
AAC bare conductor
Code name | Aluminum Area |
Stranding& Wire Diameter |
Approx Overall Diameter |
Approx Weight |
Breaking Load |
DC Resistance |
||
Al | Steel | |||||||
AWG | mm 2 | No./mm | No./mm | mm | Kg/km | KN | Ohm/km | |
Turkey | 6 | 13.30 | 6/1.68 | 1/1.68 | 5.04 | 53.75 | 5303 | 2.157 |
Swan | 4 | 21.18 | 6/2.12 | 1/2.12 | 6.36 | 85.57 | 8302 | 1335 |
Swanate | 4 | 21.12 | 7/1.96 | 1/2.61 | 6.53 | 99.56 | 10642 | 1352 |
Sparrow | 2 | 33.59 | 6/2.67 | 1/2.67 | 8.01 | 135.70 | 12653 | 0.854 |
Raven | 1/0 | 53.52 | 6/3.37 | 1/3.37 | 10.10 | 216.20 | 19455 | 0.536 |
Quail | 2/0 | 67.32 | 6/3.78 | 1/3.78 | 11.30 | 272.00 | 23529 | 0.426 |
Pigeon | 3/0 | 85.14 | 6/4.25 | 1/4.25 | 12.80 | 344.00 | 29417 | 0.337 |
Penguin | 4/0 | 107.20 | 6/4.77 | 1/4.77 | 14.30 | 433.40 | 37055 | 0.268 |
Waxwing | 266800 | 135.00 | 18/3.09 | 1/3.09 | 15.50 | 430.50 | 30519 | 0.213 |
Merlin | 336400 | 170.20 | 18/3.47 | 1/3.47 | 17.40 | 542.90 | 38487 | 0.169 |
Linnet | 336400 | 170.60 | 26/2.89 | 7/2.25 | 18.30 | 689.90 | 62918 | 0.169 |
Hawk | 477000 | 241.6 | 26/3.44 | 7/2.67 | 21.80 | 975.50 | 86011 | 0.120 |
Dove | 556500 | 282.6 | 26/3.72 | 7/2.89 | 23.6 | 1142.00 | 100838 | 0.1030 |
Peacock | 605000 | 306.2 | 24/4.03 | 7/2.69 | 24.2 | 1159.00 | 95861 | 0.0948 |
Drake | 795000 | 402.5 | 26/4.44 | 7/3.45 | 28.1 | 1626.00 | 138669 | 0.0717 |
Rail | 954000 | 483.8 | 45/3.70 | 7/2.47 | 29.6 | 1602.00 | 115626 | 0.0597 |
Code Name |
Size (KCM) |
Strand |
Approx.EC Cond with Equivalent Resistance |
Stranding |
Diameter(in) |
Cross Sectional Area (Sq in) |
Weight per 1000ft (lbs) |
Rated Strength (lbs) |
Resistance Ohms/1000ft (lbs) |
||
Individual Wires |
Complete Cable |
DC @ 20ºC |
AC@ 75ºC |
||||||||
Akron |
30.58 |
7/w |
6 |
6/1 |
.0661 |
.198 |
.0240 |
28.7 |
1,110 |
.659 |
.785 |
Alton |
48.69 |
7/w |
4 |
6/1 |
.0834 |
.250 |
.0382 |
45.7 |
1,760 |
.414 |
.493 |
Ames |
77.47 |
7/w |
2 |
6/1 |
.1052 |
.316 |
.0608 |
72.7 |
2,800 |
.260 |
.310 |
Azusa |
123.3 |
7/w |
1/0 |
6/1 |
.1327 |
.398 |
.0968 |
115.7 |
4,460 |
.163 |
.195 |
Anaheim |
155.4 |
7/w |
2/0 |
6/1 |
.1490 |
.447 |
.1221 |
145.9 |
5,390 |
.130 |
.154 |
Amherst |
195.7 |
7/w |
3/0 |
6/1 |
.1672 |
.502 |
.1537 |
183.7 |
6,790 |
.103 |
.123 |
Alliance |
246.9 |
7/w |
4/0 |
6/1 |
.1878 |
.563 |
.1939 |
231.8 |
8,560 |
.0816 |
.0973 |
Butte |
312.8 |
19/w |
266.8 |
26/7 |
.1283 |
.642 |
.2456 |
293.6 |
11,000 |
.0644 |
.0769 |
Canton |
394.5 |
19/w |
336.4 |
26/7 |
.1441 |
.721 |
.3098 |
370.3 |
13,300 |
.0511 |
.0610 |
Cairo |
465.4 |
19/w |
397.5 |
26/7 |
.1565 |
.783 |
.3655 |
436.9 |
15,600 |
.0433 |
.0518 |
Darien |
559.5 |
19/w |
477.0 |
26/7 |
.1716 |
.858 |
.4394 |
525.5 |
18,800 |
.0360 |
.0431 |
Elgin |
652.4 |
19/w |
556.5 |
26/7 |
.1853 |
.927 |
.5124 |
612.4 |
21,900 |
.0309 |
.0371 |
Flint |
740.8 |
37/w |
636.0 |
26/7 |
.1415 |
.991 |
.5818 |
695.5 |
24,400 |
.0272 |
.0327 |
Greely |
927.2 |
37/w |
795.0 |
26/7 |
.1583 |
1.108 |
.7282 |
870.4 |
30,500 |
.0217 |
.0263 |
Zhengzhou Jinshui Industry & Commerce Co.Ltd is located in the national class Zhengzhou high and new technology industries zone in Zhengzhou ,Henan province. We have owned a number of exclusive essential manufacturing technologies and have passed ISO 9001 Quality Management System ,ISO 14001 Environmental Management System ,OHSAS18001 occupational Heath Management System ,ISO 10012 Measurement Management System and others from China and abroad.
We have been engaged in producing electric cable and wire for nearly 20 years, and we are also 12-year gold supplier. And we are confident that we can offer the best service and quality for you.
Our product range is as following:
*Bare conductors(AAC, AAAC, ACSR, Galvanized steel wire)
*Aerial Bounded Cable (Duplex, Triplex, Quadruplex)
* PVC insulated wire (Rated voltage to 450/750V)
*THHN/THWN wire
*PVC insulated Power Cable
*XLPE insulated Power Cable
*Rubber-sheathed Cable
*Control Cable
*Welding Cable
*Cable AccessoriesWe take part in many fairs and exhibitions in China and abroad . Our aim is to be our customer's factory in Zhengzhou ,China.
We are here to help you place orders of cost-effective electric cable and keep tracking your products and shipment.
1.Professional production lines, and experienced workers ensure the production of everything is fine and accurate.
2, We choose excellent raw materials carefully to ensure the quality and meet the need of customers.
3.Mechanical testing of Cables is done to determine the quality and mechanical characteristics before delivery.
Welcome your inquiry! ! !