Application: The cables are designed for aerial power lines and room-entrance wires with voltage up to and including 0.6/1KV.
Used for overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. which improves the safety and reliance on electrified wire netting.
Standard: National Standard IEC and ASTM
Rated Voltage: 0.6/1KV, 11KV, 33KV
Construction: Phase conductor: aluminum stranded(AAC)
Neutral conductor: aluminum stranded(AAC), aluminum alloy stranded(AAAC), aluminum conductor steel reinforced(ACSR)
Insulation: XLPE or PE
1 Type: Duplex Service Drop, Triplex Service Drop, Quadruplex Service Drop
a Duplex Service Drop
Applications: To supply 120-volt aerial service for temporary service at construction sites, and outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
b Triplex Service Drop
Applications: To supply power from the utility's lines to the consumer`s Weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
c Quadruplex Service Drop
Applications: Used to supply 3-phase power, usually from a pole-mounted transformer to the user`s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
2 Construction
a Phase Conductor construction: The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.
b Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:
Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded
Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded
Aluminum alloy 6201-T81, concentric-lay-stranded
c Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)
Alternatively, black linear low-density polyethylene (LDPE) insulation with a 75°C temperature rating is available upon request.