Type: | Bare |
---|---|
Conductor Type: | Stranded |
Application: | Overhead |
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
AAC, AAAC, ACSR, ACSR/AW, AACSR&ACAR conductor widely used in power transmission lines with various voltage levels. Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.
1. Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
Range of Diameter | Tolerance of Dia. Plus Minus |
Min.Stress at 1% Elongation | Min.Tensile Strength | Min.Elongation in 10 in. | Weight of Zinc Coating ≮ |
Ratio of Mandrel Diameter to Wire OD for Adhersion Test | |
(in.) | (mm) | (mm) | (N/mm2) | (N/mm2) | (%) | (g/m2) | |
0.0500-0.0599 | 1.270-1.521 | 0.038 0.025 | 1310 | 1450 | 3.0 | 183 | 3 |
0.0600-0.0749 | 1.524-1.902 | 0.038 0.025 | 1310 | 1450 | 3.0 | 198 | 3 |
0.0750-0.0899 | 1.905-2.283 | 0.051 0.051 | 1310 | 1450 | 3.0 | 214 | 3 |
0.0900-0.1039 | 2.286-2.639 | 0.051 0.051 | 1280 | 1410 | 3.5 | 229 | 4 |
0.1040-0.1199 | 2.642-3.045 | 0.051 0.051 | 1280 | 1410 | 3.5 | 244 | 4 |
0.1200-0.1399 | 3.048-3.553 | 0.076 0.051 | 1240 | 1410 | 4.0 | 259 | 4 |
0.1400-0.1799 | 3.556-4.569 | 0.102 0.076 | 1170 | 1380 | 4.0 | 274 | 5 |
0.1800-0.1899 | 4.572-4.822 | 0.102 0.076 | 1170 | 1380 | 4.0 | 305 | 5 |
Range of Diameter | Tolerance of Dia. |
Tensile Strength ≮ |
Min.Elongation in. |
Resistivity at 20oC≯ | ||||
(in.) | (mm) | (mm) | Average (N/mm2) |
Individual (N/mm2) |
Average (%) |
Individual (%) |
Average (Ωmm2/m) |
Individual (Ωmm2/m) |
0.2100-0.1801 | 5.334-4.575 | +1% | 165 | 159 | 2.1 | 2.0 | 0.028172 | 0.028264 |
0.1800-0.1501 | 4.572-3.813 | +1% | 165 | 159 | 2.0 | 1.9 | 0.028172 | 0.028264 |
0.1500-0.1401 | 3.810-3.559 | +1% | 169 | 162 | 1.9 | 1.8 | 0.028172 | 0.028264 |
0.1400-0.1201 | 3.556-3.051 | +1% | 172 | 162 | 1.8 | 1.7 | 0.028172 | 0.028264 |
0.1200-0.1101 | 3.048-2.797 | +1% | 176 | 165 | 1.7 | 1.6 | 0.028172 | 0.028264 |
0.1100-0.1001 | 2.794-2.545 | +1% | 179 | 169 | 1.6 | 1.5 | 0.028172 | 0.028264 |
0.1000 | 2.540 | +1% | 186 | 176 | 1.6 | 1.5 | 0.028172 | 0.028264 |
0.0999-0.0901 | 2.537-2.289 | +0.025 | 186 | 176 | 1.6 | 1.5 | 0.028172 | 0.028264 |
0.0900-0.0801 | 2.286-2.035 | +0.025 | 190 | 179 | 1.6 | 1.5 | 0.028172 | 0.028264 |
0.0800-0.0701 | 2.032-1.781 | +0.025 | 193 | 183 | 1.6 | 1.4 | 0.028172 | 0.028264 |
0.0700-0.0601 | 1.778-1.527 | +0.025 | 197 | 186 | 1.5 | 1.3 | 0.028172 | 0.028264 |
0.0600-0.0501 | 1.524-1.273 | +0.025 | 200 | 186 | 1.4 | 1.2 | 0.028172 | 0.028264 |
(1)Are you the factory or trading company?
We are the manufacturer and 12 years gold supplier on alibaba.We are engaged in exporting cables for nearly 15 years.
(2).When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
(3).How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
(4). What is the payment terms?
30% deposit by T/T,70% T/T after checking the copy of B/L. Or irrevocable L/C at sight .
(5).What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.
Suppliers with verified business licenses