• AAC Conductor 20/75/100/200 mm Stranded Cable
  • AAC Conductor 20/75/100/200 mm Stranded Cable
  • AAC Conductor 20/75/100/200 mm Stranded Cable
  • AAC Conductor 20/75/100/200 mm Stranded Cable
  • AAC Conductor 20/75/100/200 mm Stranded Cable

AAC Conductor 20/75/100/200 mm Stranded Cable

Type: Bare
Conductor Type: Stranded
Application: Overhead
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
AAC Conductor 20/75/100/200 mm Stranded Cable pictures & photos
AAC Conductor 20/75/100/200 mm Stranded Cable
US $1 / Meter
Min. Order: 3,000 Meters
Diamond Member Since 2007

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
AAC
Conductor Material
Aluminum
Material Shape
Round Flat
Certification
ISO9001, CE, CCC
Brand
Jinshui
Material
Aluminum
Color
Wihite
Size
75/100/650
Transport Package
Wood Drum, Steel Drum, Steel- Wood Drum
Trademark
Jinshui
Origin
Zhengzhou, China
HS Code
7614900000
Production Capacity
3000km Per Month

Product Description


ACSR(Aluminum Conductor Steel Reinforced) is widely used in the overhead power distribution system of our country.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, ASTM B232, CSA C49, DIN48204, JIS C3110, customer special specification also can be satisfied.
This series includes: ABC cable, All aluminum conductors (AAC), All aluminum alloy conductors (AAAC), Aluminum conductor steel reinforced (ACSR), Anti-corrosion type ACSR, All steel conductors
Relative manufacturing standards: IEC61089, ASTM B231, B232, BS215, DIN48204 Packing: Wooden drum
1. Detailed Product Description

ACSR is used in power transmission lines. We are in the production base and have decades of experience.


AAC, AAAC, ACSR, ACSR/AW, AACSR&ACAR conductor widely used in power transmission lines with various voltage levels. Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.
1. Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power
1. Applications
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
2. Construction
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.
AAC Conductor 20/75/100/200 mm Stranded Cable
AAC Conductor 20/75/100/200 mm Stranded Cable
AAC Conductor 20/75/100/200 mm Stranded Cable
All Aluminum Conductor is in Accordance with BS215-1-70
Nominal Area
(mm2)
Stranding Wire No. and Dia.
(No./mm)
Calculated Area
(mm2)
Approx Overall Dia.
(mm)
Approx Weight
(kg/km)
Calcualted Min. Breaking Load(KN) Calculated D C Resistance at 20oC(Ω/km) Code Name
22 7/2.06 23.33 6.18 63.88 3.99 1.2270 Midge
25 7/2.21 26.85 6.63 73.53 4.59 1.0660 Gnat
35 7/2.59 36.88 7.77 101.00 6.02 0.7762 Mosquito
50 7/3.10 52.83 9.30 144.70 8.28 0.5419 Ant
60 7/3.40 63.55 10.20 174.00 9.90 0.4505 Fly
70 7/3.78 78.54 11.34 215.10 11.97 0.3645 Earwing
100 7/4.39 106.00 13.17 290.20 16.00 0.2702 Wasp
150 19/3.25 157.60 16.25 433.60 25.70 0.1825 Hornet
200 19/3.78 213.20 18.90 586.60 32.40 0.1349 Chafer
250 19/4.22 265.70 21.10 731.20 40.40 0.1083 Cockroach
300 19/4.65 322.70 23.25 887.70 48.75 0.08916 Butterfly
350 37/3.78 327.60 25.06 1021.00 57.29 0.07739 Drone
400 37/4.09 415.20 26.46 1145.00 63.10 0.06944 Centipede
450 37/4.09 486.20 28.63 1341.00 73.82 0.05930 Maybug
500 37/4.27 529.80 27.89 1461.00 80.14 0.05442 Scorpion
600 37/4.65 628.30 32.55 1732.00 94.91 0.04590 Cicada



Aluminum Conductor Steel Reinforced is in Accordance with ASTM B232-81.
Aluminum Sectional Area Stranding No. and Dia.
(No./mm)
Approx. Overall Dia Approx. Weight Calculated Breaking Load Calculated D C Resistance at 20oC Code Name
Cir.mils or AWG (mm2) Al. St. (mm) (kg/km) (KN) (Ω/km)
6 13.30 6/1.68 1/1.68 5.04 53.75 5,303 2.157 Turkey
4 21.18 6/2.12 1/2.12 6.36 85.57 8,302 1.335 Swan
4 21.12 7/1.96 1/2.61 6.53 99.56 10,642 1.352 Swanate
2 33.59 6/2.67 1/2.67 8.01 135.70 12,653 0.854 Sparrow
2 33.54 7/2.47 1/3.30 8.24 158.60 16,171 0.852 Sparate
1 42.41 6/3.00 1/3.00 9.00 171.40 15,852 0.676 Robbin
1/0 53.52 6/3.37 1/3.37 10.10 216.20 19,455 0.536 Raven
2/0 67.32 6/3.78 1/3.78 11.30 272.00 23,529 0.426 Quail
3/0 85.14 6/4.25 1/4.25 12.80 344.00 29,417 0.337 Pigeon
4/0 107.20 6/4.77 1/4.77 14.30 433.40 37,055 0.268 Penguin

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
AAC Conductor 20/75/100/200 mm Stranded Cable pictures & photos
AAC Conductor 20/75/100/200 mm Stranded Cable
US $1 / Meter
Min. Order: 3,000 Meters
Diamond Member Since 2007

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
14
Year of Establishment
2001-11-26