Overhead Bare Aluminum Conductor Steel Reinforced Conductor ACSR Aluminum Wire

Product Details
Customization: Available
Application: Overhead
Voltage: Low and Medium Voltage Cable
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
14
Year of Establishment
2001-11-26
  • Overhead Bare Aluminum Conductor Steel Reinforced Conductor ACSR Aluminum Wire
  • Overhead Bare Aluminum Conductor Steel Reinforced Conductor ACSR Aluminum Wire
  • Overhead Bare Aluminum Conductor Steel Reinforced Conductor ACSR Aluminum Wire
  • Overhead Bare Aluminum Conductor Steel Reinforced Conductor ACSR Aluminum Wire
  • Overhead Bare Aluminum Conductor Steel Reinforced Conductor ACSR Aluminum Wire
  • Overhead Bare Aluminum Conductor Steel Reinforced Conductor ACSR Aluminum Wire
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
acsr
Insulation Material
Bare
Sheath Material
No
Material Shape
Round Wire
Wire Core Material
Steel
Certification
ISO, CCC, CE
Model
ACSR
Brand
Jinshui
Packaging
Wooden Drum
Transport Package
Wooden Drum
Specification
Any standard
Trademark
Jinshui
Origin
China
HS Code
76141000
Production Capacity
3000 Kilometer / Year

Packaging & Delivery

Package Size
1100.00cm * 400.00cm * 600.00cm
Package Gross Weight
500.000kg

Product Description

Product Description

1. Applications


Conductor(AAC and ACSR) have been widely used in power transmission lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost large transmission capacity. And they are also suitable for laying across rivers valleys and the places where special geographical features exist.

2. Service Performance

(1). The permissible long-time operating temperature for aerial conductor is 70oC.

(2). Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area, the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.

(3). When connecting conductors, the conductor beside the connecting tube cant be prominent. Otherwise, the force on the operating conductors will be unbalanced. After connectors are install, the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.

(4). Under installaion, the arc downing stress of all the conductors should be the same. With in the permissible distance of crossing buildings or dropping to the ground, the stress can be 10-15% higher than regular stress.

3. Product Performance

(1). The electrical performance of AAC and ACSR is indicated in DCΩ /km(20oC). The resistivity of the hard aluminum wire for stranded wires is not greater than 28.264 nΩ . M of international standard value.

(2). The rated tensile strength of AAC is denoted with the result of total cross-section of all aluminum conductors multiplied by min. Tensile of corresponding size specified in the standard for aluminum wire.

(3). The rated tensile strengh of ACSR is denoted with sum of all aluminum conductorstensile strength and steels tensile strength.

A. The tensile strength of all aluminum conductors is denoted with the result of all cross-sections of aluminum conductors multiplied by min. Tensile strength of corresponding size specified in the standard for aluminum wire.

B. The tensile strength of all steel wire is denoted with the result of all cross-sections of steel wires multiplied by the stress at 1% elongation of corresponding size specified in the standard for steel wire.

4. Material Standard

(1). The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889: 1987).

(2). The zinc coated steel wire used for ACSR conforms to IEC 60888: 1987.

(3). Production can be arranged according to customers requirements for material standard, etc.

Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced
Overhead Bare Aluminum Conductor Steel Reinforced Conductor ACSR Aluminum WireOverhead Bare Aluminum Conductor Steel Reinforced Conductor ACSR Aluminum Wire

 

Company Profile

Zhengzhou Jinshui Industry & Commerce Co.Ltd is located in the national class Zhengzhou high and new technology industries zone in Zhengzhou ,Henan province. We have owned a number of exclusive essential manufacture technologies and has pass ISO 9001 Quality Management Systerm ,ISO 14001 Environmental Management Systerm ,OHSAS18001 occupational Heath Management Systerm ,ISO 10012 Measurement Management Systerm and others from China and abroad.

We have been engaged in producing electric cable and wire for nearly 20 years, and  we are also 12 year gold supplier. And we are confident that we can offer the best service and quality for you .

Our product range is as following:
 
*Bare conductors(AAC, AAAC, ACSR, Galvanized steel wire)
 *Aerial Bounded Cable (Duplex, Triplex,Quadruplex)
 * PVC insulated wire (Rated voltage to 450/750V)
 *THHN/THWN wire
 *PVC insulated Power Cable
 *XLPE insulated Power Cable 
 *Rubber sheathed Cable 
 *Control Cable
 *Welding Cable 
 *Cable Accessories

We take part in many fairs and exhibitions in China and abroad . Our aim is to be our customer's factory in Zhengzhou ,China . 
We are here to help you placing orders of cost-effective electric cable and keep tracking your products and shipment.

Overhead Bare Aluminum Conductor Steel Reinforced Conductor ACSR Aluminum Wire


===========================================================

* Our Factory * 
==========================================================  

1,Professional production lines, experienced worker, ensure the production of every thing is fine and accurate.
Overhead Bare Aluminum Conductor Steel Reinforced Conductor ACSR Aluminum Wire
2,We choose excellent raw materials carefully to ensure the quality and meet the need of customers.

Overhead Bare Aluminum Conductor Steel Reinforced Conductor ACSR Aluminum Wire

3,Mechanical testing of Cables is done to determine the quality and mechanical characteristics  before delivery.
Overhead Bare Aluminum Conductor Steel Reinforced Conductor ACSR Aluminum Wire





=====================================================
*FAQ*      
=====================================================

(1)Are  you the factory or trading company?
We are the manufacturer and 12 years gold supplier.We are engaged in exporting cables for nearly 15 years.
 (2).When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
(3).How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
(4). What is the payment terms?
30% deposit by T/T,70% T/T after checking the copy of B/L. Or irrevocable L/C at sight .
(5).What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.